| Mfg. Part # | Mfg. Name | CAGE | RNCC | RNVC | ISC | MSDS | SADC | DAC | HCC |
|---|---|---|---|---|---|---|---|---|---|
| 984081-325 | L-3 COMMUNICATIONS CORPORATION | 11447 | 3 | 2 | 2 | ||||
| 984081-325 | LOCKHEED MARTIN CORP | 49671 | 5 | 9 | 2 | ||||
| CP1 | CENTRAL RESISTOR CORP | 33224 | 3 | 1 | 2 | ||||
| HFCW7004F | BEMAN MFG INC | 20895 | 5 | 1 | 2 |
| MRC | Requirement Statement | Characteristics |
|---|---|---|
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 85.0 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | NOT RATED |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | 0.0 TO 800.0 |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | NOT RATED |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AARB | TERMINAL TYPE | WIRE LEAD |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| ADAQ | BODY LENGTH | 0.938 INCHES NOMINAL |
| AEFB | POWER DISSIPATION RATING IN WATTS | 1.000 FREE AIR |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| ABPM | BODY DIAMETER | 0.293 INCHES NOMINAL |
| AAPP | ELECTRICAL RESISTANCE | 7.000 MEGOHMS |