Home > Switches > FSC 5930 > 5930-01-043-5895

5930-01-043-5895, 5930010435895 NSN Information

Request for Quote

Manufacturer Part Number(s):1211236-500, 330098/3, M1 175 135 272, M24236/1-0500, M555N135B175, MIL-PRF-24236/1, MIL-S-24236/1

FSC NIIN ITEM NAME
5930 010435895 SWITCH,THERMOSTATIC
INC ESDC HMIC
0045 P

5930-01-043-5895 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
1211236-500 LOCKHEED MARTIN CORPORATION 56232 C 1 5 N
330098/3 SENSATA TECHNOLOGIES INC 82647 C 1 5 F
M1 175 135 272 SENSATA TECHNOLOGIES INC 82647 C 1 5
M24236/1-0500 MILITARY SPECIFICATIONS 81349 2 2 5
M555N135B175 HONEYWELL INTERNATIONAL INC 97896 C 1 5
MIL-PRF-24236/1 MILITARY SPECIFICATIONS 81349 4 1 5
MIL-S-24236/1 MILITARY SPECIFICATIONS 81349 5 9 5

5930-01-043-5895 Characteristics

MRC Requirement Statement Characteristics
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION
CQYJ MOUNTING FACILITY PATTERN TWO POSITION IN-LINE
AEJN DISTANCE BETWEEN MOUNTING FACILITY CENTERS 0.937 INCHES NOMINAL
ABPM BODY DIAMETER 0.540 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
SR-1 SPEC/STD CONTROLLING DATA
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL FIRST VOLTAGE 28.0 DC AT SEA LEVEL SECOND VOLTAGE
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
SR-1 DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M24236/1-0500
ADAU BODY HEIGHT 0.280 INCHES MINIMUM AND 0.395 INCHES MAXIMUM
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.140 INCHES NOMINAL
ABKW OVERALL HEIGHT 0.659 INCHES NOMINAL
STYL STYLE DESIGNATOR DISC W/FLANGE
SR-1 MANUFACTURERS CODE 81349
CTYX CONTACT STIMULUS RATING 135.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 175.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT
ABHP OVERALL LENGTH 1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM
FREQ FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CSCF TERMINAL TYPE TAB, SOLDER LUG
AKBY TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CTYC CONTACT ADJUSTABILITY DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE
CTHF CONTACT LOAD CURRENT RATING 2.0 AMPERES RESISTIVE LOAD AND 1.0 AMPERES INDUCTIVE LOAD AND 500.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE 5.0 AMPERES RESISTIVE LOAD AND 2.5 AMPERES INDUCTIVE LOAD AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE
ABTD MOUNTING SLOT WIDTH 0.140 INCHES NOMINAL
AXGY MOUNTING METHOD BRACKET AND SLOT AND UNTHREADED HOLE
SR-1 NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-PRF-24236/1
CQGB CONTACT ACTION STIMULUS DECREASE