| MRC |
Requirement Statement |
Characteristics |
| ADAQ |
BODY LENGTH |
4.515 INCHES MINIMUM AND 4.546 INCHES MAXIMUM |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.484 INCHES MINIMUM AND 3.515 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AAJF |
(NON-CORE DATA) THREAD DIRECTION |
RIGHT-HAND |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| ADAU |
BODY HEIGHT |
3.437 INCHES MAXIMUM |
| FEAT |
SPECIAL FEATURES |
MUST FUNCTION IN A LIQUID COOLED POWER SUPPLY PER FC 77 |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.109 INCHES MINIMUM AND 2.140 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CQLC |
(NON-CORE DATA) WINDING TAP LOCATION |
MULTIPLE TAPS W/CENTER TAP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| AEHZ |
III MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
22 TURRET |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| ACZD |
III TRANSFORMER WINDING CONNECTION TYPE |
DELTA-WYE |
| ADAT |
BODY WIDTH |
2.984 INCHES MINIMUM AND 3.015 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
416.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| AAJD |
(NON-CORE DATA) THREAD CLASS |
2B |
| CBME |
(NON-CORE DATA) CUBIC MEASURE |
47.1 CUBIC INCHES |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT |