Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-849-2763

5925-00-849-2763, 5925008492763 NSN Information

Request for Quote

Manufacturer Part Number(s):114135, 335C757H43, 377058, 3AM17MG3-10-120-208AC400-54, 3XAM17-10-208VAC400C54, 3XAM17-10-218V400CPS54, DMS83059

FSC NIIN ITEM NAME
5925 008492763 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-849-2763 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
114135 AIR LOGISTICS CORPORATION 01413 E 8 1
335C757H43 NORTHROP GRUMMAN SYSTEMS CORPORATION 97942 5 9 1
335C757H43 WESTINGHOUSE ELECTRIC CORP 79500 5 9 1
377058 JOY TECHNOLOGIES INC. 32537 5 9 1
3AM17MG3-10-120-208AC400-54 EATON CORP 74193 5 9 1
3XAM17-10-208VAC400C54 EATON CORP 74193 5 9 1
3XAM17-10-218V400CPS54 EATON CORP 74193 3 9 1
DMS83059 DLA LAND AND MARITIME 16236 5 9 1

5925-00-849-2763 Characteristics

MRC Requirement Statement Characteristics
TTQY TERMINAL TYPE AND QUANTITY 6 TAB W/SCREW
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
ABXD BUSHING LENGTH 0.120 INCHES MINIMUM AND 0.140 INCHES MAXIMUM
ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF AND FUNGUS PROOF
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.180 INCHES MINIMUM AND 1.200 INCHES MAXIMUM
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 15.000 MINIMUM AT 200 PCT AND 45.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3500.0 AC ALL LOCATIONS
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.990 INCHES MINIMUM AND 2.010 INCHES MAXIMUM
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNC
ADAT BODY WIDTH 2.263 INCHES MINIMUM AND 2.283 INCHES MAXIMUM
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.802 INCHES MINIMUM AND 1.822 INCHES MAXIMUM
CMLP THREAD QUANTITY PER INCH 32
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC ALL LOCATIONS
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AKPX POLE QUANTITY 3
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 218.0 AC ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE