Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-925-3727

5925-00-925-3727, 5925009253727 NSN Information

Request for Quote

Manufacturer Part Number(s):351-590-040, 454-0058-019, AM33HEMG6-30-250-4-60, AM33HEMG6-30-250VAC60C4

FSC NIIN ITEM NAME
5925 009253727 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-925-3727 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
351-590-040 INTERSTATE ELECTRONICS CORPORATION 07421 5 2 3
454-0058-019 BOEING COMPANY THE 94756 3 2 3
AM33HEMG6-30-250-4-60 EATON CORP 74193 5 9 3
AM33HEMG6-30-250VAC60C4 EATON CORP 74193 5 9 3

5925-00-925-3727 Characteristics

MRC Requirement Statement Characteristics
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 2.5 AC AND 1.0 DC
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 4 THREADED STUD
ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 250.0 AC AND 50.0 DC
CPRW ACTUATOR FUNCTION TRIP-RESET
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE TWO
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CRTK SWITCH TERMINAL TYPE TURRET
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
ADAT BODY WIDTH 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNC
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
FREQ FREQUENCY IN HERTZ 60.0 ALL LOCATIONS
PKWT III UNPACKAGED UNIT WEIGHT 8.750 OUNCES
AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 CONTROL
CMLP THREAD QUANTITY PER INCH 32
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT AND EXPLOSION RESISTANT
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
AKPX POLE QUANTITY 2
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.000 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 130.0 ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE