| MRC |
Requirement Statement |
Characteristics |
| AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.750 INCHES NOMINAL |
| CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 AC ALL LOCATIONS |
| CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
0.800 MINIMUM AND 3.000 MAXIMUM ALL LOCATIONS |
| CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE, TWO, AND THREE LINKED |
| AJEC |
BOSS HEIGHT |
0.156 INCHES NOMINAL |
| CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
| CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC ALL LOCATIONS |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
3.359 INCHES NOMINAL |
| CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY ALL LOCATIONS |
| CPRQ |
RESET METHOD |
MANUAL |
| ADAT |
BODY WIDTH |
3.052 INCHES NOMINAL |
| CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
| CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC ALL LOCATIONS |
| FREQ |
FREQUENCY IN HERTZ |
400.0 ALL LOCATIONS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 THREADED STUD |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 THREADED HOLE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
65.0 AMPERES AC ALL LOCATIONS |
| ADTV |
CASE MATERIAL |
PLASTIC |
| AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
3.063 INCHES NOMINAL |
| CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
| CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
3 TOGGLE |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND MOISTURE RESISTANT AND EXPLOSION RESISTANT |
| BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES |
| AKPX |
POLE QUANTITY |
3 |
| CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
| CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
| CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.300 MINIMUM AT 200 PCT AND 1.000 MAXIMUM AT 200 PCT AND 0.100 MINIMUM AT 300 PCT AND 0.300 MAXIMUM AT 300 PCT AND 0.040 MINIMUM AT 400 PCT AND 0.150 MAXIMUM AT 400 PCT ALL LOCATIONS |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
1.031 INCHES NOMINAL |
| CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
| ADAQ |
BODY LENGTH |
3.719 INCHES NOMINAL |
| AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
1.031 INCHES NOMINAL |