| MRC |
Requirement Statement |
Characteristics |
| ACDC |
CURRENT TYPE |
DC |
| AKDJ |
PRIME MOVER TYPE |
ELECTRIC MOTOR |
| ATWN |
LOAD LIMIT AT SELECTED SPEED AND DRUM LOCATION |
2200.0 POUNDS ZERO TO FULL SPEED FIRST DRUM 2200.0 POUNDS ZERO TO FULL SPEED SECOND DRUM |
| ATWF |
DRUM FLANGE DIAMETER AND LOCATION |
16.000 INCHES NOMINAL FIRST DRUM 16.000 INCHES NOMINAL SECOND DRUM |
| ACSY |
FURNISHED ITEMS AND QUANTITY |
1 MOTOR CONTROLLER AND 1 PAY OUT MECHANISM |
| AKPS |
DUTY CYCLE |
INTERMITTENT |
| ADZC |
ENVIRONMENTAL PROTECTION |
WATERTIGHT |
| ATWP |
TRAVEL RATE PER MINUTE |
60.0 FEET |
| AAXH |
PRIME MOVER QUANTITY |
1 |
| ATYG |
POWER REQUIREMENT RATING |
10.00 HORSEPOWER |
| ATYH |
DRUM SURFACE DESIGN |
PLAIN |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ELEC |
VOLTAGE IN VOLTS |
230.0 |
| SR-5 |
THE MANUFACTURERS DATA |
|
| APHE |
OPERATION METHOD |
POWER |
| ATWD |
DRUM FLANGE TO FLANGE DISTANCE AND LOCATION |
8.000 INCHES NOMINAL FIRST DRUM 8.000 INCHES NOMINAL SECOND DRUM |
| BFMF |
COOLING METHOD |
ANY ACCEPTABLE |
| ATWE |
DRUM DIAMETER AND LOCATION |
8.625 INCHES NOMINAL FIRST DRUM 8.625 INCHES NOMINAL SECOND DRUM |
| AWFA |
DRUM DESIGNATION |
LEFT-HAND OR RIGHT-HAND |
| SR-5 |
MANUFACTURERS CODE |
72907 |
| SR-5 |
DESIGN CONTROL REFERENCE |
1189D1 |
| ATWS |
BRAKING METHOD |
MANUAL |