FSC NIIN ITEM NAME
5925 000892721 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-089-2721 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
256-230-101 WOOD ELECTRIC OPERATIONS POTTER AND 79405 5 9 2
271-1545P1 RAYTHEON COMPANY 49956 5 9 2
271-1545P1 RAYTHEON TECHNICAL SERVICES COMPANY 3B150 3 2 2
APL111-1392-270 SENSATA TECHNOLOGIES MARYLAND INC 81541 5 2 2
PAM333MG6-30-250-400 EATON CORP 74193 5 9 2
W93X13-2-30 WOOD ELECTRIC OPERATIONS POTTER AND 79405 5 9 2
W93X13-2-30 TYCO ELECTRONICS CORPORATION 77342 5 9 2

5925-00-089-2721 Characteristics

MRC Requirement Statement Characteristics
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 30.0 AMPERES AC ALL LOCATIONS
ADAQ BODY LENGTH 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNC
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
AJEC BOSS HEIGHT 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
CMLP THREAD QUANTITY PER INCH 32
ADAT BODY WIDTH 2.240 INCHES MINIMUM AND 2.260 INCHES MAXIMUM
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 130.0 ALL LOCATIONS
PKWT III UNPACKAGED UNIT WEIGHT 9.500 OUNCES
AKPX POLE QUANTITY 3
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.689 INCHES MINIMUM AND 2.813 INCHES MAXIMUM
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT AND 8.000 MAXIMUM AT 200 PCT ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE