Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-119-3242

5925-00-119-3242, 5925001193242 NSN Information

Request for Quote

Manufacturer Part Number(s):AM17-15-32VDC55, GC885N15A55

FSC NIIN ITEM NAME
5925 001193242 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-119-3242 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
AM17-15-32VDC55 EATON CORP 74193 3 9 2
GC885N15A55 NORTHROP GRUMMAN SYSTEMS CORPORATION 26512 7 2 2

5925-00-119-3242 Characteristics

MRC Requirement Statement Characteristics
ADAT BODY WIDTH 0.750 INCHES NOMINAL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.812 INCHES NOMINAL
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED EXPLOSION RESISTANT
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.400 MINIMUM AT 200 PCT AND 7.500 MAXIMUM AT 200 PCT SINGLE LOCATION
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 3000.0 DC SINGLE LOCATION
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES DC SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW
CPRQ RESET METHOD MANUAL
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
BBRJ III SPECIAL HANDLING FEATURE MAGNETIC
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
AAQL BODY STYLE SINGLE POLE TYPE
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.000 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
PKWT III UNPACKAGED UNIT WEIGHT 4.250 OUNCES
AKPX POLE QUANTITY 1
TEST TEST DATA DOCUMENT 26512-GC885N15A55 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 32.0 DC SINGLE LOCATION
ADAQ BODY LENGTH 2.500 INCHES NOMINAL
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 0.750 MINIMUM AND 3.500 MAXIMUM SINGLE LOCATION
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.190 INCHES NOMINAL
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE