Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-110-9266

5925-00-110-9266, 5925001109266 NSN Information

Request for Quote

Manufacturer Part Number(s):JA2-C3-6-P

FSC NIIN ITEM NAME
5925 001109266 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-110-9266 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
JA2-C3-6-P EATON CORP 74193 3 9 2

5925-00-110-9266 Characteristics

MRC Requirement Statement Characteristics
CPRL TRIP RELEASE CHARACTERISTIC INSTANTANEOUS ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
AJEC BOSS HEIGHT 0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC ALL LOCATIONS
CPRQ RESET METHOD MANUAL
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 6.0 AMPERES AC ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 4 TAB, SOLDER LUG
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC ALL LOCATIONS
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 2 TOGGLE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED DUSTPROOF
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
THSD THREAD SERIES DESIGNATOR UNC
ADAT BODY WIDTH 1.468 INCHES MINIMUM AND 1.532 INCHES MAXIMUM
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 1000.0 AC ALL LOCATIONS
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AKPX POLE QUANTITY 2
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
ADAQ BODY LENGTH 1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE AND TWO LINKED
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE